qiao@hvtest.cc15871365102
  • YDJ Digital Display 10kVA Oil Immersed AC DC Hipot Tester

    YDJ Digital Display 10kVA Oil-Immersed AC/DC Hipot Tester is a high-capacity electrical testing system that combines reliable oil-immersed insulation with modern digital control. Featuring robust 10kVA output and precise digital monitoring, this tester delivers accurate AC/DC dielectric strength validation for power transformers and other high-voltage equipment in laboratory and industrial applications.

    Product Details of YDJ Digital Display 10kVA Oil Immersed AC DC Hipot Tester



    DSC08569-Введение в продукт

    The YDJ Digital Display 10kVA AC/DC Hipot Test Equipment is a high-capacity, modern testing system designed for comprehensive dielectric strength validation. Combining a robust 10kVA rating capable of testing large equipment such as power transformers and long cables with precise digital monitoring of test parameters, it performs both AC and DC withstand voltage tests with automated control and data recording. This advanced equipment is particularly suitable for high-voltage laboratories, manufacturer quality control, and utility commissioning tests where accurate documentation and reliable high-power output are essential.



    0021

    Product Characteristics

    Premium Materials & Reliable Quality – The high-voltage test transformer is built with carefully selected materials, ensuring reliable performance and excellent operational stability.

    High Voltage Margin & Low Partial Discharge – Designed with a generous voltage margin, a compact corona ring, and minimal partial discharge levels for superior electrical performance.

    Compact & Lightweight Design – Utilizes advanced new insulation materials, resulting in reduced size and lighter weight for enhanced portability and ease of installation.




    Технические параметры

    specifications and modelscapacity(kVA)High Voltage(kV)high-tension current(mA)ow input voltageratio of transformation(high /rites)temperature rise℃(30 minutes)
    tension(V)electricity(A)
    ЯДЖ-3/50350602001550010
    ЯДЖ-5/505501002002550010
    ЯДЖ-10/5010502002005050010
    ЯДЖ-20/5020504004005050010
    ЯДЖ-30/5030506004005050010
    ЯДЖ-50/5050501000400125500
    10
    ЯДЖ-5/100510050200251000
    10
    ЯДЖ-10/10010100100400251000
    10
    YDJ-10/251025400400251000
    10
    ЯДЖ-20/10020100200400501000
    10
    ЯДЖ-30/1003010030040075100010
    ЯДЖ-50/10050100500400125100010
    YDJ-15/1501515010040037.5100010
    ЯДЖ-20/1502015013340050100010
    ЯДЖ-30/1503015020040075100010
    ЯДЖ-50/15050150333400125100010
    ЯДЖ-100/150100150667400250100010
    ЯДЖ-50/20050200250400125100010
    ЯДЖ-100/200100200500400250100010
    ЯДЖ-150/200150200750400375100010
    ЯДЖ-200/2002002001000400500100010
    ЯДЖ-300/2003002001500400750100010
    ЯДЖ-50/30050300170400125100010
    ЯДЖ-100/300100300333400250100010
    ЯДЖ-150/300150300500400375100010
    ЯДЖ-200/300200300667400500100010
    ЯДЖ-300/3003003003000400750100010


    AC DC Hipot Test Set 7
    AC DC Hipot Test Set 8


    Advantage

    1. Excellent insulation performance. This type of transformer uses transformer oil as the insulation medium, and its breakdown field strength is much higher than that of air medium. It can stably output high voltage during the test process and perfectly adapt to the withstand voltage performance testing of medium and high voltage equipment (such as power cables, high voltage switches, etc.), effectively ensuring the accuracy of test data.

    2. Outstanding heat dissipation efficiency. By relying on the oil circulation heat dissipation mechanism, the heat generated during the operation of the equipment can be carried away in a timely manner. Even in long-term continuous pressure testing scenarios, it can maintain a stable working state and avoid testing interruptions or equipment losses caused by overheating.

    3. Widely applicable. Through the independent operation of a single unit or the combination of multiple series and parallel units, oil immersed test transformers can achieve flexible coverage of voltage levels ranging from several kV to several thousand kV and capacities ranging from several kVA to several hundred kVA. They can meet the diverse withstand voltage testing needs of different industries and specifications of electrical equipment, and have strong adaptability.

    4. It combines durability and safety. Adopting a sealed fuel tank design can effectively isolate external moisture and dust, reduce equipment maintenance frequency and cost; At the same time, transformer oil has good arc extinguishing performance, combined with the explosion-proof structural design of the equipment itself, which can significantly reduce safety risks during the testing process and ensure the safety of operators and the testing environment.


    Main application scenarios

    Power system: AC withstand voltage test for circuit breakers, isolating switches, and current transformers.

    Cable testing: Conduct a boost pre-test on high-voltage power cables before DC withstand voltage or series resonance (note that oil transformers are usually not suitable for variable frequency series resonance, mainly used for excitation transformers with power frequency or series resonance).

    Insulation material testing: Conduct breakdown strength tests on insulation boards, insulation paints, silicone rubber, etc. in the laboratory.


    Frequently Asked Questions

    1. Can it be connected in cascade for higher voltage testing?
    Yes. Multiple oil-immersed test transformers can be connected in cascade to achieve ultra-high output voltages for GIS, long power cables, large transformers, and other high-voltage equipment.
    2. What insulating oil is used?
    We normally use high-quality transformer insulating oil with excellent dielectric strength and cooling performance. Eco-friendly insulating oil options are also available upon request.
    3. How often should the insulating oil be replaced?
    Under normal operating conditions, the oil should be periodically inspected. Replacement depends on oil quality and operating environment. Oil dielectric strength testing is recommended before replacement.









    Вам также может понравиться

    • Посетите нас

      Корпус 6, Оптико-механический промышленный парк «Долина оптики», 84 Gaoxin 5 Road,
      Зона развития новых технологий Восточного озера, город Ухань, провинция Хубэй, Китай

    • Свяжитесь с нами по электронной почте

      qiao@hvtest.cc

    • Позвоните нам

      +86-15871365102